Restartoffice
 
How to find the Modem version These init strings were tested. | Back to Tech Support
We accept donations. Home | Products | Support | Tech Support | Security | Site Map | Feedback
Modem Buffer adjustment Email Problems ? | Modem Drivers
Modem errors : If you get a modem error after you add an init command, remove the init string and reboot the computer. You may have to upgrade the drivers or if the modem is an older model, it may refuse to work with the init command. Remove the init string and reboot the computer. If you still get a modem error, uninstalling and reinstalling should get it going, if the modem is good.
Modem name Disable v.92 Disable v.90 Disable v92 & v90 Other init used
3 Com 56K v.90 mini pci               ATZ
3 Com windows modem ti.....( 33.6K )               s32=98
56 HP Pci V.92           +MS=V34,0    
56HP92-PCT           +ms=v34,0    
56HP92-D (cmodem version 12)       n0s37=13        
56K AC-Link voice modem (version)   Not a   V.90   Modem   ATZ
56K Internet fax (v.90) ( version 5.34 )       -v90=0        
56K Internet fax (v.90) ( version 5.56 )               -v90=0s10=200
Actiontec MD560 RD v.92 MDC   +MS=V34,0            
Actiontec 56K v.90 modem ( 5.79a )       -v90=0        
Agere Win Modem (version 8.30)   NO   init   needed    
Aopen FM56P 56K               ATZ
Aztech -- See Drivers under SmartLink                
BCM V.90 56K modem       -v90=0       S32=66
BCM V.92 56K modem           +MS=V34,0   ATZ
Broadxent V.92 ( version Di3631 )   +MS=11,0            
Broadxent V.92 ( version Di3652-1)   +ms=11,0            
Compaq data fax modem(v90 k56flex)       n0s37=13        
Compaq 56K v.90 ( HSF modem )       +MS=K56,0        
Compaq 336-DF 56K Upgradable               ATZ
CNXT V.92 pci modem   AT+MS=V34,0            
Conexant 56k Ac-Link data fax (ver.12)       n0s37=13        
Conexant D 480 MDC V.92 (Laptop)   +MS=V34,0            
Conexant HCF v.90 56k RTAD spkr.       +MS=V34,0        
Conexant HCF v.90 56K Data Fax pci       +MS=K56,0       s10=200
Conexant HSFi v.92 mini pci           +MS=v34,0    
Conexant HSFi v92 56k DF pci           +MS=v34,0    
Conexant HSF v.92 56K RTAD           +MS=v34,0    
Conexant Smart HSFi v92 56k DF           +MS=V34,0    
Conexant Soft 56k m... v92 ready pci           +MS=v34,0    
Conexant Soft 56 modem (v90)       +MS=V90,0        
Conexant Soft K56 pci modem M               ATZ
Conexant Soft K56 data fax TAM               ATZ
Creative modem blaster V.92 Di5652   +MS=11,0            
Creative modem blaster flash 56               ATZ
Dell data fax modem (v90 HCF 56k)       n0s37=13        
ESS ES 56 CVM-Pi data fax voice       +ms=11,0        
ESS ES 56 STH-Pi data fax voice       +MS=11,0        
ESS ES 56T-Pi data fax       +ms=11,0        
ESS Superlink-Mdata               ATZ
ESS Superlink-N ( version V90A )       +MS=11,0        
Fujitsu LB Global LTmodem(ver. 5.43)       -v90=0        
Generic HCF data fax modem (ver.19)       +MS=K56,0        
Generic HCF data fax modem (ver.43)       +ms=k56,0       at+ms=k56,0
Generic 56k HCF data fax (ver.19)       n0s37=13        
Generic Soft K 56 data,fax,voice       +MS=V90,0        
GTW v.92 Voice modem   +MS=v34,0            
Modem name Disable v.92 Disable v.90 Disable v.92&v.90 Other init used
HCF V90 56k data fax pci ( k56 flex )       n0s37=13        
HSP56 MicroModem (V.92) 9.00-9k           +ms=v34,0    
HSP56 MicroModem (V.90)       n0s37=13       n0s37=13s10=200
HSP56 MicroModem (V.90) 8.00-9k   No   init   needed    
HSP56 MR ( V.90 )       n0s37=13        
HSP56 MR -M8575 (V.90) (Laptop)       n0s37=13        
Intel® V.92 Ham data fax voice               ATZ
Intel® 536 EP V.92       at+ms=v34,1,0,0       ATZ
Lucent v.90 modem       -v90=0        
Lucent Win Modem(v.92) version 8.28   No   init   needed   s10=200
Lucent Win Modem(v.92) version 8.27   No   init   needed    
Lucent Win Modem(v.92) version 8.26   No   init   needed    
Lucent Win Modem(v.92) version 8.24   No   init   needed    
Lucent Win Modem(v.92) version 8.23   Did not   connect   with +MS=V34,0    
Lucent Win Modem(v.92 version 8.20)   +MS=V34,0            
Lucent Win Modem(v.92 version 8.12)   +MS=V34,0            
Lucent Win Modem(v.92 version 8.09)   +MS=V34,0            
Lucent Win Modem(v.90 version 6.00)       +MS=V34,0        
Lucent Win Modem(v.90 version 5.98a)       +ms=v34,0        
Lucent Win Modem(v.90 version 5.98)       +MS=V34,0        
Lucent Win Modem(v.90 version 5.84)       +MS=V34,0        
Lucent Win Modem(v.90 version 5.79)       -v90=0       -v90=0s10=200
Lucent Win Modem(v.90 version 5.75)       -v90=0        
Lucent Winmodem (v.90 version 5.66)       -v90=0        
Lucent Win Modem(v.90 version 5.48)       -v90=0        
Lucent Win Modem(v.90 version 5.39)       -v90=0        
Lucent Winmodem (v.90 version 5.30)       -v90=0        
Lucent Win Modem(v.90 version 5.15)       -v90=0        
Lucent Winmodem ( older )       -v90=0        
Lucent v90+DSL ( v90+dsl wild fire )       -v90=0        
LT Winmodem (older)       -v90=0       ATZ
LT Winmodem ( v90 version 5.41G6 )       n0s37=13        
LT Winmodem ( v90 version 5.04 )       -v90=0        
MDP3800-W fax modem (chipset)       ATZ+MS=V34        
MDP3858-U modem(v90 version 29)       n0s37=13        
MDP3880-W (U) pci modem (V.90)       n0s37=13        
MDP3900 V-U modem ( version 12 )       -v90=0       n0s37=13
MDP7800-U pci modem(ver. 5.41G6)       n0s37=13        
MDP7800-U modem (version 5.17)       at-v90=0        
Motorola SM56 pci speaker-phone       *mm13        
Neteligent 56K Fax       -v90=0        
PCTEL 2304 WT v.92 MDC (Laptop)   +MS=V34,0            
PCTEL Platinum v.90 (version 8.00-9k)   No   init   needed    
PCTEL Platinum V90       n0s37=13       -v90=0
Rockwell HCF 56k data fax (ver.11)   Not a   V.90   Modem   ATZ
Rockwell HCF 56k data fax (ver.19)       +MS=K56,0        
Rockwell HCF 56k speakerphone       n0s37=13       n0s37=13s10=200
Rockwell HCF data fax (k56 flex v.90)       n0s37=13        
SupraMax 56i ( v.90 )       -v90=0        
SmartLink, See Drivers for SmartLink                
SupraMax 56i voice pci(k56 flex v.90)       n0s37=13        
SupraMax 56i Voice Pci V.92           +MS=v34,0    
Supra SST 56i DFV       -v90=0        
Telepath internet 56k win (5.41G6)       n0s37=13        
Telepath 56K for Windows               S25=100
Telepath Windows modem with X2   No   init   used    
Toshiba V.90 data fax voice (laptop)       -v90=0s38=1        
Toshiba software modem (Laptop)               ATZ
Modem name Disable v.92 Disable v.90 Disable v.92&v.90 Other init Used
U.S. Robotics 56K ( v.92 external )               S25=100
U.S. Robotics 56K Fax Win               ATZ
U.S. Robotics 56K voice Int PNP               S25=100
U.S. Robotics 56K Voice Win               ATZ
V.90 Pci Windows "LHV" modem               ATZ
v.90 Pci winmodem       s38=0-v90=0        
Xircom card bus ethernet 100+modem               No init used
Zoom 56K pci fax modem (version 5)       -v90=0        
Zoom V92 Pci           +MS=v34,0    
Zoom V92 Pci fax modem (version 8)           at&fs38=0-v90=1    
Zoom V.92 USB fax modem (k56flex)       n0s37=13        
Zoom 56k modem (v90 version 5.75)       -v90=0        
                 
The above init commands worked when everything else was properly setup and they were entered correctly. Verify that they are typed in exactly as you intended. Use them at your own risk.

Modem Buffer adjustment : If you have to adjust the buffers to get around line noise, dropped connections or email problems, the Receive Buffer should be 1 step lower than the Transmit Buffer.

Note : If a modem has two strings that can work, use only one or the other, not both of them together. Only use the init specified for that modem, using the wrong init could make the modem connect at 14400 or 9600 BPS.

Note: Some modems may not have an init command for disabling v.90 or v.92, however, the command in "Other init used' was used to help a modem get connected to the Internet.

Windows XP: Windows XP users may have to 'uncheck' the LCP and Multilink boxes in the PPP settings to get some V.90 and V.92 modems to connect.

Modem type or version : To find the modem type or version number ( v.92 or v.90 or neither), open Control Panel, open Modems or Phone and Modem Options, then perform a Diagnostics or Query and look through the response section of the results.

Note : Lucent win modem version 8.23 is a V.92 modem that did not connect when using +MS=v34,0 to disable V.92 . However it will connect without an init string / extra command.

Some newer 'E Machines' have a Conexant Soft 56K pci modem, but on the front label says " V.92 ready pci ", +MS=v34,0 worked in that case.
Donations will help us improve the information on this site so we can serve you better. Top of Page
     
  Init is the abbreviation for Initialization. Restartoffice.com
   
 